Multiparameter Portable Water Quality Meter Model 900P

High performance multiparameter water quality meter includes 8 measurement modes, the meter is suitable for measuring the pH, ORP, Ion concentration, Conductivity, TDS, Salinity, Resistivity and Dissolved Oxygen of the liquids.

pH Mode:
• Portable multiparameter water quality meter is equipped with a large backlit LCD display.
• 1 to 5 points push-button calibration with auto-buffer recognition.
• Selectable pH buffer standard (USA/NIST/DIN) or using the custom calibration solutions.
• Automatic electrode slope display helps user decide whether to replace sensor.

ORP Mode:
• Single point offset calibration allows adjusting the displayed value to a known standard.
• Relative and absolute millivolt measurement modes provide accurate ORP readings.

Ion Mode:
• 2 to 5 points calibration including the eight concentration calibration points can be selected.
• Automatically recognize ion selective electrodes, does not need to specify type of ion.
• Direct ion concentration readout simplifies the elaborate measurement process.
• Selectable multiple concentration units includes the ppm, mg/L, mmol/L and mol/L.

Conductivity/TDS/Salinity/Resistivity Mode:
• 1 to 5 points push-button calibration with automatic calibration solution recognition.
• Selectable cell constant (0.1/1/10), normalization temperature (20/25°C), TDS conversion
  factor, seawater and practical salinity measurement mode.
• Linear or pure water compensation improves measurement accuracy of meter.

Dissolved Oxygen Mode:
• 1 or 2 points calibration using air-saturated water and zero oxygen solution.
• Manual salinity and barometric pressure compensation improve the measurement accuracy.

Features:

• Automatic Temperature Compensation provides accurate reading over the entire range.
• Calibration Due Reminder prompts user to calibrate the meter regularly.
• Stability indicator automatically shows current measurement status.
• Auto-Hold function freezes stable measured value for easy viewing and recording.
• Manual temperature calibration corrects temperature deviation.
• Selectable temperature unit (°C or °F) meets different application requirements.
• Automatic electrode diagnosis shows zero point offset and slope of the electrode.
• Help message as a operational guide that helps you quickly begin using the meter.
• System menu allows setting the 15 parameters, including the number of calibration points,
  resolution, stability condition, measurement units, etc.
• Reset feature automatically resumes all parameters back to factory default options.
• Expanded memory stores and recalls up to 500 readings.
• Built-in real-time clock stamps stored data to meet GLP standard.
• Stored data can be transferred into computer by USB communication interface.
• Multi-mode power scheme (battery, power adapter, computer's USB port) ensures that use
  the meter smoothly.

Model

900P

pH

 

Range

-2.000~20.000pH

Accuracy

±0.002pH

Resolution

0.1, 0.01, 0.001pH

Calibration Points

1 to 5 points

Calibration Solutions

USA, NIST, DIN or User-defined

Temperature Compensation

0~100°C, 32~212°F

Compensation Mode

Manual or Automatic

mV

 

Range

-1999.9~1999.9mV

Accuracy

±0.2mV

Resolution

0.1, 1mV

Calibration Points

1 point (Only for Relative mV mode)

Calibration Range

±200mV

Ion

 

Range

0.001~19999ppm, mg/L, mol/L (Refer to the range of ISE)

Accuracy

±0.5% F.S (Monovalent), ±1% F.S (Divalent)

Resolution

0.001, 0.01, 0.1, 1

Calibration Points

2 to 5 points

Calibration Solutions

0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000ppm, mg/L, mol/L

Temperature Compensation

0~100°C, 32~212°F

Compensation Mode

Manual or Automatic

Conductivity

 

Range

0~20.00, 200.0, 2000µS/cm, 20.00, 200.0mS/cm

Accuracy

±0.5% F.S

Calibration Points

1 to 5 points

Calibration Solutions

10µS/cm, 84µS/cm,1413µS/cm,12.88mS/cm,111.8mS/cm

Temperature Compensation

0~100°C, 32~212°F, Manual or Automatic

Temperature Coefficient

0.0~10.0%/°C

Compensation Modes

Linear or Pure Water

Cell Constant

K=0.1, 1, 10 or User-defined

Normalization Temperature

20°C or 25°C

TDS

 

Range

0~10ppt (Max. 20ppt, depending on factor setting)

Accuracy

±1% F.S

TDS Factor

0.1~1.0 (Default 0.5)

Salinity

 

Range

0~10ppt (Max. 80ppt)

Accuracy

±1% F.S

Measurement Modes

Seawater or Practical Salinity

Resistivity

 

Range

0~100MΩ

Accuracy

±1% F.S

Resolution

0.01, 0.1, 1

Dissolved Oxygen

 

Range

0.00~20.00mg/L (or ppm)

Accuracy

±0.2mg/L

Resolution

0.01mg/L

Calibration Points

1 or 2 points

Temperature Compensation

0~50°C, 32~122°F, Automatic

Pressure Correction

60.0~112.5kPa, 450~850mmHg

Salinity Correction

0~50g/L

% Saturation of Oxygen

 

Range

0.0~200.0%

Accuracy

±2.0%

Resolution

0.1, 1%

Temperature

 

Range

0~105°C, 32~221°F

Accuracy

±0.5°C, ±0.9°F

Resolution

0.1°C

Calibration Points

1 point

Calibration Range

Measured value ±10°C

Others

 

Hold Function

Manual or Automatic

Stability Conditions

Low or High

Calibration Due

0 to 31 days

Power Off

Manual or Automatic (10, 20, 30 minutes)

Reset Function

Yes

Memory

Stores up to 500 data sets

Output

USB Communication Interface

Connector

BNC, 6-pin Mini Plug

Power Requirements

3×1.5V "AA" Batteries

Battery Life

Approximately 150 hours (Turn off the backlit)

Dimensions

170(L)×85(W)×30(H)mm

Weight

300g

Order